Decontamination

Dental Decontamination

Autoclaves & Washer Disinfectors

Autoclaves & Washer Disinfectors

Ai Dental provides HTM and En13060 Compliant validation and maintenance for your autoclaves, washer disinfectors and ultrasonic baths. Our validation and maintenance packages provide you with fully compliant, transparent and cost effective solution to evidence compliance with new legislation including HTM0105 and MHRA.

What is involved?

Service / Validation Autoclaves

  • Check for signs of wear and tear and note
  • Drain and clean reservoir
  • Check/Clean reservoir water level sensors
  • Replace washers as required
  • Clean the chamber and door face
  • Clean or replace the filter as required
  • Replace the door seal
  • Check the door micro switch operation and adjust if required
  • Check electrical connections (mains cable and fuse connections etc.)
  • Refill reservoir with distilled/deionised water ready to test
  • Check the safety relief valve
  • Fit temperature probes
  • Run test cycles 134˚C (target temperature 135.5˚C + 1˚C)
  • Check for steam/water leaks
  • Verify that all gauges operate correctly
  • Verify all door lock operation
  • Remove temperature probe (ensure cover of the test port is replaced)
  • Complete all paperwork
  • Validation to HTM0105

 

Service / Validation Washer Disinfector

  • Check for signs of wear and tear and note
  • Drain and clean reservoir
  • Check/Clean reservoir water level sensors
  • Replace washers as required
  • Clean the compartment and door face
  • Clean or replace the filter as required
  • Replace the door seal as required
  • Check the door micro switch operation and adjust if required
  • Check electrical connections (mains cable and fuse connections etc.)
  • Run test cycles
  • Check for water leaks
  • Verify correct cycles and readings
  • Verify all door lock operation
  • Complete all paperwork
  • Validation to HTM0105 (HTM2030)

 

Service / Validation Ultrasonic Baths

  • Check for signs of wear and tear and note
  • Drain and clean tank
  • Check/Clean water level sensors
  • Check the door micro switch operation and adjust if required
  • Check electrical connections (mains cable and fuse connections etc.)
  • Run test cycles
  • Check for water leaks
  • Verify correct cycles and readings
  • Verify all door lock operation
  • Complete all paperwork
  • Validation to HTM0105 (HTM2030)
Dental Decontamination

Pressure Vessel Inspection

Pressure Vessel Inspection

Pressure Vessel is a term used by Health and Safety to describe compressors, autoclaves and their associated pipe work and safety devices. Any equipment that may fail due to a build up of pressure in a system requires testing; this will form the basis of a compliance to Pressure Systems Safety Regulations 2000 and the Provision and Use of Work Equipment Regulations (PUWER) 1992.

What is involved?

  • Switch off & drain air
  • Thoroughly clean the exterior
  • Inspect all welds, check all joints and seals for leaks
  • Remove the safety relief valve
  • Test the pressure of the safety relief valve and replace
  • Check inside the tank for any signs of corrosion or cracking
  • Switch on, check again for any air leaks
  • Check all correct pressures are reached
  • Complete all paperwork

Engineering

Ai Dental has the experience and capabilities to provide full engineering services to your dental practices, including dental decontamination.

Our team of engineers are trained by the equipment manufacturer and are committed to providing an excellent service.

Each engineer is trained in all disciplines, meaning they can not only inspect your X-Ray unit but will also service your autoclave, your compressor, repair your suction pump and other practice equipment as well as offering you valuable advice on your equipment before you make a purchase.